Alarms Desktop |
The Alarms desktop is used to view and to acknowledge alarm events. Alarm events are defined in the Event Parameter menu (System > Event Parameters). Any event can be defined as an alarm event. Alarm events require operator acknowledgement and are displayed in the Alarms desktop. A schedule must be defined for all alarms (System > Event parameters, Alarm settings). When an alarm is generated during a valid schedule, operators have to acknowledge the alarm. Alarms are displayed with date and time, alarm description, details, instructions (if defined) and associated graphic or video clip. New events are added at the bottom of the Alarm desktop unless you have setup the list to display in descending order (in the Alarm Desktop Properties dialog).
Defining an Alarms Desktop
1 - From the Desktop main window, select the desktop in which you want to display alarm messages, then define the window type: Floating or Desktop type.
2 - Specify the secondary windows that will be associated with the Alarms desktop:
•
•
•
• Graphic screen: This window will display the location of the alarm being reported (if graphics are defined in the system). For more information on assigning graphic, see Graphics Definition.
Note:
Viewing System Alarm Messages
1 - Select the Alarm desktop. Alarm events are displayed according to the criteria selected in the Sorted by field.
Note:
2 - You can double-click the log area (middle of the window) to add a comment. The Add a comment window opens and enables you to enter text data. Once you have finished and clicked the OK button to close the window, the alarm event will be preceded by a + sign, indicating that an annotation has been added to the alarm event.
Note:
3 - You may change/define the sorting order (Sorted by drop-down list):
•
•
•
•
•
4 - You may right-click anywhere in the window to enable the Properties window from which you can enable alarm status buttons:
•
•
•
•
•
5 - Select the Manual / Automatic buttons to toggle the acknowledgement method (automatic or manual). Only operators who are assigned this feature in the Operator Definition menu can use this option. For more information, see Operators Definition.
Note:
6 - Right click an alarm message to perform additional tasks on alarm events:
•
•
•
•
•
•
Displaying Alarm Desktops Automatically
EntraPass enables users to display graphics automatically - from any desktop - as soon as an alarm occurs. This feature enables operators on duty to automatically view new alarms without having to open the alarm desktop and secondary windows associated with it. If Display on new alarm is checked the alarm desktop (and its secondary windows) will be displayed as soon as an alarm occurs regardless of the active window.
1 - Define a desktop and customize it as an alarm desktop: for this, you have to check the items of the Alarms desktop section.
2 - Check the Display on new alarm option so that operators can automatically view new alarms without having to open the alarm desktop and secondary windows associated with it.
Note:
3 - Click OK and Go for your configuration to take effect immediately.
Note:
Acknowledging Alarms/Events
Usually, operators have to acknowledge receipt of an alarm condition (event—such as intrusion, input in alarm, etc.) by responding in ways such as clicking the acknowledgement button. In EntraPass, operators acknowledge alarm messages from an alarm warning box or from the Alarms desktop window.
Note: When an alarm message is acknowledged by an operator, the notification is acknowledged or removed at all workstations.
Note: A sound can be added to alarm events. For more details about setting options for an alarm sound, see Multimedia Devices Configuration.
Note:
Automatic Acknowledgement
Alarms can be automatically acknowledged without operator intervention. This option is enabled in the Operator definition menu (System > Operators > Privileges, Auto acknowledge).
Note:
Note:
To Acknowledge an Alarm Message
1 - When the Acknowledgement required message box appears, take one of the following actions:
•
•
•
•
Note:
Note:
To Acknowledge Alarms from the Alarms Desktop
Each workstation has its own alarm desktop which displays alarm events received from the server. When a workstation starts up, alarms displayed on the desktop will have a “to be updated” status (a blue button in the second column). Once communication is established with the server, all events will be updated on the alarm desktop. The blue button will then be replaced by a red button (alarm), a yellow button (flag) or a green button (acknowledged).
Note:
1 - Select the alarm event you want to acknowledge (one that has been flagged, for instance), Right-click to enable a shortcut menu.
2 - Select Acknowledge from the sub-menu. The status indicator becomes green.
Note:
Mandatory Alarm Comment
If an instruction with the Mandatory alarm comment checkbox selected in System/Instruction is assigned to an alarm, the operator will have to add a comment in order to mark the alarm as “acknowledged” (see Instructions Definition for more details).
Note:
If the alarm event has already been acknowledged, a warning message will be displayed for you to confirm that the comment should be added.